Clarified the way that elevation is used with regard to specifying a relief device (5981). Corrected an issue with heating values for components with fractional molecular formulas (1592/5296). Enabled calculation of mean residence time for a pipe with holdup (7719). Improved the Select Components search to more easily find a match based on legacy component number (7629). Implemented mode 3 (specify pressure out and power, calculate efficiency) for polytropic compressor and expander UnitOps (5567). CC-DYNAMICS: Added capability to set step size in user-defined time units (seconds, hours, etc.) for a dynamic simulation (4021). Corrected an issue with CC-THERM calculating incorrect pressure drop for a single baffle (7638). Corrected an issue with tube material data not loading properly for a heat exchanger prior to calculation (7417). Corrected an issue with liquid density displaying an incorrect unit label in the zone-by-zone analysis report (7306). Corrected an issue with the RAMP controller not receiving values from an external source such as a sensitivity analysis, controller, or Data Map (7495). Corrected an issue that prevented disabling a VBA reaction in a vessel reactor UnitOp (5024). Corrected an issue that could in rare circumstances lead to a blank UnitOp sub-palette (7874). Corrected an issue with inlet temperature calculation for a co-current heat exchanger with a specified number of zones (7802). Corrected an issue where the Currency Factor field of the Engineering Units dialog did not accept a decimal point (7771). Corrected an issue with Stream Reference UnitOp destination stream flash behavior (7737). Corrected an issue with unit operation costing not showing the correct currency (2955). Corrected an issue where column reboiler sizing did not flag CC-THERM process type to a once-through thermosyphon reboiler (1873). Added ramp information to the Stream and UnitOp Links section of the Topology report (7796). Added a 13-stream outlet icon to the Divider UnitOp sub-palette (7631). Changed the behavior of reactors (KREA, REAC, GIBBS, EREA) to use lowest inlet pressure where no reactor pressure is specified (6299). Added KREA UnitOp icons that provide inlets for the thermal mode utility option (6196).
Added the option to select a utility stream for PFR KREA (7847).Added calculated heat transfer area for utility mode to KREA specifications (5194).
Provided improved access to CEP Cost Index data via the Edit Costing Index ribbon command (5891).
#Liquid notes version series
Added the capability to save any displayed data series in a chart as a user series (7474).Added a context menu for charts with data series-specific options (7483/7760).Expanded the pipe schedule table to support JIS and DIN standards or a user pipe table (7808/6211/6252/6253).Provided easy access to all CC-THERM reports and charts directly from the CC-THERM command ribbon (2222).Created a new CC-THERM ribbon that provides a case-based, streamlined workflow for heat exchanger sizing (7593/7728).